" The boiler being thoroughly heated by a preliminary run, the fires are to be burned low and well cleaned. Note the amount of coal left on the grate as nearly as it can be estimated; note the pressure of steam and the water level. "
Stationary Engineering ... - Page 438
by Joseph Gerald Branch - 1906 - 991 pages
Full view - About this book

Transactions, Volume 5

American Society of Mechanical Engineers - 1884 - 486 pages
...slicing and cleaning fires have them burnt rather low, as is usual before cleaning, and then thoroughly cleaned, note the amount of coal left on the grate...can be estimated, note the pressure of steam and the height of the Water level (which should be at the medium height to be carried throughout the test)...
Full view - About this book

Transactions of the American Society of Mechanical Engineers, Volumes 1-5

American Society of Mechanical Engineers - 1884 - 658 pages
...slicing and cleaning fires have them burnt rather low, as is usual before cleaning, and then thoroughly cleaned, note the amount of coal left on the grate...as it can be estimated, note the pressure of steam and.the height of the water level (which should be at the medium height to be carried throughout the...
Full view - About this book

Van Nostrand's Engineering Magazine, Volume 32

1885 - 566 pages
...slicing and cleaning fires have them burned rather low, as is usual before cleaning, and then thoroughly cleaned ; note the amount of coal left on the grate...be estimated ; note the pressure of steam and the height of the water level — which should be at the medium height to be carried throughout the test...
Full view - About this book

A Treatise on Steam-boilers: Their Strength, Construction, and Economical ...

Robert Wilson - 1889 - 490 pages
...slicing and cleaning fires have them burned rather low, as is usual before cleaning, and then thoroughly cleaned ; note the amount of coal left on the grate...be estimated ; note the pressure of steam and the height of the water level — which should be at the medinm height to be carried throughout the test...
Full view - About this book

A Treatise on Steam-boiler: Their Strength, Construction, and Economical Working

Robert Wilson - 1889 - 492 pages
...rather low, as is usual before cleaning, and then thoroughly cleaned ; note the amount of coal lefi on the grate as nearly as it can be estimated ; note the pressure of steam and the height of the water level — which should be at the medium height to be carried throughout the test...
Full view - About this book

A Treatise on Steam-boilers: Their Strength, Construction, and Economical ...

Robert Wilson - 1892 - 530 pages
...rather low, as is usual before cleaning, and then thoroughly cleaned ; note the amount of coal leff on the grate as nearly as it can be estimated ; note the pressure of steam and the height of the water level — which should be at the medium height to be carried throughout the test...
Full view - About this book

A Manual of Steam-boilers : Their Design, Construction, and Operation: For ...

Robert Henry Thurston - 1890 - 704 pages
...slicing and cleaning fires have them burned rather low, as is usual before cleaning, and then thoroughly cleaned ; note the amount of coal left on the grate...be estimated ; note the pressure of steam and the height of the water-level — which should be at the medium height to be carried throughout the test...
Full view - About this book

A Handbook of Engine and Boiler Trials and of the Indicator and Prony Brake ...

Robert Henry Thurston - 1890 - 546 pages
...slicing and cleaning fires have them burned rather low, as is usual before cleaning, and then thoroughly cleaned ; note the amount of coal left on the grate...be estimated ; note the pressure of steam and the height of the water-level — which should be at the medium height to be carried throughout the test...
Full view - About this book

A Text-book of Experimental Engineering: For Engineers and for Students in ...

Rolla Clinton Carpenter - 1892 - 772 pages
...slicing and cleaning fires have them burned rather low, as is usual before cleaning, and then thoroughly cleaned ; note the amount of coal left on the grate...be estimated ; note the pressure of steam and the height of the water-level — which should be at the medium height to be carried throughout the test...
Full view - About this book

Modern Mechanism: Exhibiting the Latest Progress in Machines, Motors, and ...

Park Benjamin - 1892 - 970 pages
...slicing and cleaning fires, have them burned rather low, as is usual before cleaning, and then thoroughly cleaned ; note the amount of coal left on the grate...be estimated ; note the pressure of steam and the height of the water-level — which should be at the medium height to be carried throughout the test...