" Lap-welded flues required to carry a steam pressure exceeding 60 pounds per square inch, and not exceeding 120 pounds per square inch, and having a diameter not exceeding 16 inches and a length not exceeding 18 feet, and made in sections not exceeding... "
A Library of Steam Engineering - Page 456
by John Fehrenbatch - 1894 - 803 pages
Full view - About this book

Synopsis of the Decisions of the Treasury Department on the Construction of ...

United States. Department of the Treasury - 1894 - 1038 pages
...working steam pressure not to exceed 60 pounds per square inch, and having a diameter not exceedgin 16 inches and a length not exceeding 18 feet ; and...one into the other and substantially riveted : and AH such tubes and flues shall have a thickness of material according to their respective diameters,...
Full view - About this book

Steamboat Inspectors' Manual: Laws Governing the Steamboat Inspection ...

United States - 1895 - 360 pages
...any required length; and Lap-welded flues required to carry a working steam pressure not to exceed 60 pounds per square inch and having a diameter not exceeding...16 inches and a length not exceeding 18 feet; and Lap-welded flues required to carry a steam pressure exceeding 60 pounds per square inch and not exceeding...
Full view - About this book

The Mechanical Engineering of Power Plants

Frederick Remsen Hutton - 1897 - 788 pages
...flues required to carry a steam-pressure exceeding 60 Ibs. per square inch, and not exceeding 120 tbs. per square inch, and having a diameter not exceeding...respective diameters, as prescribed in the following table : " 10. Lap welded flues not exceeding 6 inches in diameter may be made of any required length without...
Full view - About this book

The Mechanical Engineering of Power Plants

Frederick Remsen Hutton - 1902 - 804 pages
...required length ; and lap-welded flues required to carry a working steampressure not to exceed 60 Ibs. per square inch and having a diameter not exceeding...16 inches, and a length not exceeding 18 feet ; and lap-welded flues required to carry a steam-pressure exceeding 60 Ibs. per square inch, and not exceeding...
Full view - About this book

Handbook on Engineering: The Practical Care and Management of Dynamos ...

Henry Charles Tulley - 1902 - 940 pages
...flues required to carry a steam pressure exceeding fiO Ibs. per square inch, and not exceeding 120 Ibs. per square inch, and having a diameter not exceeding...the other, and substantially riveted ; and All such flues shall have a thickness of material according to their respective diameters, as prescribed in...
Full view - About this book

Handbook on Engineering: The Practical Care and Management of Dynamos ...

Henry Charles Tulley - 1902 - 944 pages
...per square inch, and not exceeding 120 Ibs. per square inch, and having a diameter not exceeding 1G inches and a length not exceeding 18 feet, and made...the other, and substantially riveted ; and All such flues shall have a thickness of material according to their respective diameters, as prescribed in...
Full view - About this book

Steam-boilers: Their Theory and Design

Harry de Berkeley Parsons - 1903 - 394 pages
...inch and having a diameter not exceeding 16 indies and a length not exceeding 18 feet; and Lup-welded flues required to carry a steam pressure exceeding...respective diameters, as prescribed in the following table. CORRUGATED FURNACE-FLUES. Outside Diameter. Inches. 1 U 1} if 2 2* 24 2j 3 Thickness. Inch. .072 .072...
Full view - About this book

Steam-boilers: Their Theory and Design

Harry de Berkeley Parsons - 1903 - 396 pages
...steam pressure exceeding 60 pounds per square inch and not exceeding 120 pounds per square inch, find having a diameter not exceeding 16 inches and a length not exceeding J8 feet, and made in sections not exceeding 5 feet in length, and fitted properly one into the other,...
Full view - About this book

Steam-boilers, Their Theory and Design

Harry de Berkeley Parsons - 1905 - 404 pages
...length not exceeding 18 feet; and Lap-welded flues required to carry a steam pressure exceeding tMi pounds per square inch and not exceeding 120 pounds...to their respective diameters, as prescribed in the follow ing table. CORRUGATED FURNACE-FLUES. Corrugated furnace-flues constructed with corrugations...
Full view - About this book

The Mechanical Engineering of Steam Power Plants

Frederic Remsen Hutton - 1908 - 912 pages
...per square inch, and not exceeding 120 Ibs. per square inch, and having a diameter not exceeding 10 inches and a length not exceeding 18 feet, and made...respective diameters, as prescribed in the following table' Outside Diameter. Thickness. Outside Diameter. Thickness. Outside Diameter. Thickness. Outside Diameter....
Full view - About this book