Hidden fields
Books Books
" ... of having a flange turned over at right angles to the body of the tube to the width required by the applicable material specifications. "
Locomotive and Boiler Inspector's Handbook - Page 212
by Adam J. O'Neil - 1929 - 274 pages
Full view - About this book

Report of Proceedings of the ... Annual Convention of the ..., Volume 50

American Railway Master Mechanics' Association - 1918 - 678 pages
...5. Flange Tests. — (a) For all tubes except superheater pipes, a test specimen not less than 4 in. in length shall have a flange turned over at right angles to the body of the tube, without showing cracks or flaws. This flange, as measured from the outside of the tube, shall be }& in. wide...
Full view - About this book

Steam-boilers, Their Theory and Design

Harry de Berkeley Parsons - 1905 - 408 pages
...over 0.045 per cent 6. Chemical analyses will not be required for charcoal iron tubes. Flange Test. a. A test specimen not less than 4 inches in length shall...over at right angles to the body of the tube without showing cracks or flaws. This flange as measured from the outside of the tube shall be f inch wide....
Full view - About this book

General Rules and Regulations Prescribed by the Board of Supervising ...

United States. Department of Commerce and Labor. Steamboat Inspection Service - 1906 - 154 pages
...metal without showing cracks or flaws, with bend at one side being in the weld. (5) A second tube to have a flange turned over at right angles to the body of the tube and to have a width equal to three-eighths of an inch. All the work to be done cold. Each tube shall...
Full view - About this book

Selected Standard Specifications, Volumes 1-4

American Society for Testing Materials - 1912 - 440 pages
...PROPERTIES AND TESTS. 4. A test specimen not less than 4 in. in length shall have a flange f in. wide turned over at right angles to the body of the tube without showing cracks or flaws. 5. A test specimen 4 in. in length shall stand hammering flat until the inside...
Full view - About this book

Year-book

1913 - 420 pages
...PHYSICAL PROPERTIES AND TESTS. 4. (a) A test specimen not less than 4 in. in length shall Flange Tests. have a flange turned over at right angles to the body of the tube, without showing cracks or flaws. This flange, as measured from the outside of the tube, shall be f in. wide...
Full view - About this book

Book of Standards

National Tube Co - 1913 - 614 pages
...and smaller and on all sizes of seamless tubes, a flange threeeighths (%) of an inch wide shall be turned over at right angles to the body of the tube without showing crack or opening at the weld. Internal Pressure Test. Each Lap-welded tube shall be subjected...
Full view - About this book

Report of Proceedings of the ... Annual Convention of the ..., Volume 47

American Railway Master Mechanics' Association - 1914 - 886 pages
...each of which shall conform to the requirements specified. III. PHYSICAL PROPERTIES AND TESTS. 4. (a) A test specimen not less than 4 inches in length shall...flange turned over at right angles to the body of the tubes without showing cracks or flaws. This flange as measured from the outside of the tube shall be...
Full view - About this book

Transactions of the American Society of Mechanical Engineers, Volume 36

American Society of Mechanical Engineers - 1915 - 1412 pages
...specified. III PHYSICAL PROPERTIES AND TESTS 167 Flange Test, a A test specimen not less than 4 in. in length .shall have a flange turned over at right angles to the body of the tube without showing cracks or flaws. This flange as measured from the outside of the tube shall be % in. wide....
Full view - About this book

Mechanical Engineers' Handbook

Lionel Simeon Marks - 1916 - 1922 pages
...charcoal iron. Seamless tubea shall be made of open-hearth steel. A test specimen not leas than 4 in. in length shall have a flange turned over at right angles to the body of the tube without showing cracks or flaws. This flange as measured from the outside of the tube shall be 9s, in. wide....
Full view - About this book

A.S.T.M. Standards

1916 - 806 pages
...specified. III. PHYSICAL PROPERTIES AND TESTS. Flange Tests. 4. (fl) A test specimen not less than 4 in. in length shall have a flange turned over at right angles to the body of the Position afterUsing Flaring Too/-.., .•Position : afterdsina . Flatter. A - Outs. D/'am of Flue /essj"....
Full view - About this book




  1. My library
  2. Help
  3. Advanced Book Search
  4. Download EPUB
  5. Download PDF